GOVERNANCE CENTER

Governance should execute—not sit in a PDF nobody reads.

METRAXIOM treats public utility, calculation models, AI capabilities, commercial activation and measurement authority as separately versioned and gated systems. A feature being technically possible does not mean it is authorized.

RELEASE PROFILE · PUBLIC_USE_PRODUCTION
LIVE ENVIRONMENT POSTURE

Independent gates

The public-use release model keeps useful public tools and context-only provider signals separable from purchasing, private controlled work, candidate providers, and authoritative measurement release.

ONPublic Builder
ONPublic fixed-layout PDF
ONContext Twin provider execution
ONPublic indexing
OFFNew paid enrollment
OFFBilling + cancellation portal
OFFSigned Stripe reconciliation
OFFReference Intelligence
OFFInterrogate AI
OFFChatGPT / MCP
OFFAuthoritative release
REFERENCE MODEL REGISTRY

Every Workbench formula has a name and version.

Reference-only models can help a technician work quickly, but they cannot silently become a controlled certificate, validated method or authoritative release.

1.0.0

SI prefix scaling

MW-SI-PREFIX · reference only

Scale SI quantities across the complete official decimal prefix range.

Assumptions: SI prefix symbols are case-sensitive. · Decimal powers of ten only; binary prefixes are out of scope.
1.0.0

Measurement-unit conversion

MW-UNIT-CONVERT · reference only

Convert common calibration-lab quantities through an explicit reference unit.

Assumptions: Only units within the same declared quantity family may be converted. · Affine temperature conversion is handled separately from linear conversions.
1.1.0

Range intelligence

MW-RANGE-INTELLIGENCE · reference only

Expose span, range position, headroom, error percentages, ppm, resolution provenance and user-declared multi-term accuracy allowance without hiding the range basis.

Assumptions: Range high is greater than range low. · Specification count terms and full-scale display counts are different concepts. · Count-derived span/count arithmetic does not by itself prove physical instrument resolution. · Range selection is not automated without a validated device profile.
1.0.0

Resolution-limited reporting

MW-REPORT-RESOLUTION · reference only

Preview a value rounded to an explicitly declared resolution while preserving higher internal calculation precision.

Assumptions: Declared resolution is supplied with provenance. · Half-even rounding is a reporting policy, not evidence that the instrument actually possesses the declared resolution.
1.0.0

Digital quantization uncertainty reference

MW-DIGITAL-QUANTIZATION · reference only

Calculate the standard uncertainty corresponding to a uniform quantization model over plus/minus one-half declared resolution.

Assumptions: Uniform quantization over ±resolution/2 is explicitly justified for the measurement system. · Do not add this contribution automatically when another model already accounts for quantization/resolution.
1.0.0

Tolerance, guard band and TUR reference

MW-DECISION-REF · reference only

Expose error, specification limits, guarded acceptance limits and a declared demonstration TUR convention.

Assumptions: Inclusive boundaries. · TUR convention = minimum tolerance magnitude / expanded uncertainty. · This reference tool does not select a decision rule for the user.
1.0.0

Independent-component RSS uncertainty

MW-UNC-RSS · reference only

Combine independent standard uncertainty contributors and apply an explicit coverage factor.

Assumptions: Contributors are independent unless a controlled covariance model is used elsewhere. · Sensitivity coefficients are explicit.
1.0.0

Type A repeatability statistics

MW-TYPE-A-REPEAT · reference only

Evaluate repeated independent observations obtained under the same conditions as a Type A statistical contribution.

Assumptions: At least two observations are required. · Observations are independent and obtained under the same measurement conditions. · This evaluates repeatability/statistical contribution; it is not a complete uncertainty budget.
1.0.0

Effective degrees of freedom

MW-WELCH-SATTERTHWAITE · reference only

Approximate effective degrees of freedom for mutually independent standard-uncertainty components.

Assumptions: Components are mutually statistically independent. · Degrees of freedom are supplied or explicitly treated as infinite. · Correlation/covariance requires a different validated model.
1.0.0

Ohm's Law and DC power

MW-OHMS-LAW · reference only

Solve voltage, current, resistance and power when two electrical quantities are known.

Assumptions: DC/resistive model. · Resistance must remain positive. · Complex impedance and phase are outside this model.
1.0.0

Kirchhoff balance checks

MW-KCL-KVL · reference only

Check signed current and voltage sums against a user-declared residual tolerance.

Assumptions: Users assign signs consistently with the selected node/loop convention.
1.0.0

Linear transmitter scaling

MW-LINEAR-SCALE · reference only

Map common electrical signals such as 4–20 mA or 0–10 V into engineering-unit ranges.

Assumptions: Linear transfer function. · No sensor nonlinearity, trim, square-root extraction or environmental correction unless separately modeled.
1.0.0

Calibration error / correction / ppm

MW-ERROR-STATS · reference only

Calculate indication error, correction, relative error and ppm against a declared reference.

Assumptions: Reference value is nonzero for relative/ppm quantities.
1.0.0

Frequency / period reciprocal

MW-FREQ-TIME · reference only

Convert positive frequency to period and positive period to frequency.

Assumptions: Steady periodic signal.
1.0.0

AC reactance and ideal resonance reference

MW-AC-REACTANCE · reference only

Calculate ideal capacitive reactance, inductive reactance, and LC resonant frequency from explicitly declared frequency and component values.

Assumptions: Ideal lumped-element model. · Frequency, capacitance, and inductance are positive. · Loss, ESR, parasitics, Q, phase, distributed effects, and RF fixture behavior are outside this model.
1.0.0

Reading-set descriptive statistics

MW-DATASET-SUMMARY · reference only

Summarize a technician reading set with deterministic decimal count, sum, mean, median, extrema, range and bounded repeatability statistics.

Assumptions: Readings carry the same declared quantity and unit. · Sample standard deviation and standard uncertainty of the mean require at least two observations. · Descriptive statistics do not establish measurement validity, independence, stability or calibration authority.
1.0.0

Working-register scalar arithmetic

MW-SCALAR-ARITH · reference only

Perform bounded deterministic arithmetic on a carried working value without exposing a general expression evaluator.

Assumptions: Addition and subtraction require the second operand to be expressed in the same carried unit. · Multiplication and division treat the second operand as dimensionless. · This model does not perform dimensional synthesis or infer new derived quantities.
1.0.0

Reading-set mean comparison

MW-DATASET-COMPARE · reference only

Compare the deterministic means of two analyzed reading sets without retyping values.

Assumptions: Both sets carry the same declared physical quantity and exact unit. · A difference between means does not by itself establish drift, stability, bias, significance, or conformity.