DEVICE CONNECTIVITY · ARCHITECTURE

One governed bridge between the lab bench and the evidence record.

The planned METRAXIOM Device Bridge runs locally on an approved laboratory computer and connects to supported instruments through validated protocol/model profiles. Cloud software does not directly own arbitrary USB, GPIB, serial or LAN hardware.

Initial boundary: identify and read, not adjust.

A connected instrument may supply typed evidence. Connection, discovery or an imported reading does not by itself establish calibration validity, specification authority, review, release or regulatory compliance.

CAPABILITY LADDER

Every device capability is separately authorized.

READ

discover

Detect an attached or network-visible instrument through an approved adapter without issuing measurement-changing commands.

Phase: initial · device validation required
READ

identify

Read manufacturer, model, serial, firmware or equivalent identity fields when the protocol supports them.

Phase: initial · device validation required
READ

read measurement

Read typed measurement values only through a device profile that defines quantity, units, range, status and command semantics.

Phase: initial · device validation required
READ

read status

Read readiness, error/event registers and non-destructive health/status information.

Phase: initial · device validation required
READ

read configuration

Read configuration needed to interpret a measurement without modifying the device.

Phase: initial · device validation required
READ

import evidence

Create a timestamped import envelope for readings and metadata; imported data is evidence input, not automatic calibration authority.

Phase: initial · device validation required
GATE

execute controlled procedure

Execute only an approved versioned procedure after simulator/hardware validation, role controls and rollback behavior are proven.

Phase: future_gated · device validation required
GATE

write configuration

Change device configuration only with device-specific validation, MFA/role authorization, pre/post snapshots and audit evidence.

Phase: future_restricted · device validation required
GATE

adjust or trim

Calibration adjustment, zero/trim or coefficient writes remain disabled until device-specific validation and quality-system approval exist.

Phase: future_restricted · device validation required
GATE

firmware update

Firmware operations are outside the initial bridge and require a separate validated maintenance workflow.

Phase: future_restricted · device validation required
PROTOCOL CLASSES

Standards first. Vendor adapters when necessary.

VISA

GPIB / USB / serial / TCP-IP

Common multi-vendor instrumentation API layer.

SCPI

GPIB / USBTMC / LAN / serial

Common programmable-instrument command family; exact commands remain model-profile specific.

USBTMC

USB

USB Test and Measurement Class transport.

IEEE-488 / GPIB

GPIB

Long-lived laboratory bus across calibrators, DMMs, counters and RF instruments.

LXI

Ethernet

LAN instrumentation ecosystem using approved network instrument transports.

OPC UA LADS

Ethernet / OPC UA

Manufacturer-independent laboratory and analytical device information model.

Modbus TCP

Ethernet

Common industrial/environmental instrumentation protocol; register maps are device-profile specific.

Modbus RTU

RS-485 / serial

Serial industrial protocol; function/register access is allowlisted per device profile.

RS-232 / serial

Serial

Legacy and field instruments may expose ASCII or binary command sets.

HART

4-20 mA + digital

Read-only process-variable/identity access is separated from trim and configuration writes.

FOUNDATION Fieldbus

Fieldbus

Requires approved local interface hardware and profile-aware capability boundaries.

PROFIBUS PA

Fieldbus

Requires approved local interface and device-specific validation.

Approved vendor SDK/API

Vendor-defined

Fallback when open standards do not expose required read capability; versions and licenses are pinned/reviewed.
ECOSYSTEM TARGETS

Compatibility is declared by validated profile—not by marketing sentence.

These ecosystems define the initial research/adapter targets. A vendor name here does not mean every model is supported.

Fluke Calibration

electrical calibrators · reference multimeters · pressure and temperature calibration systems

Compatibility is declared only per validated model/profile.

Keysight

DMMs · counters · power · RF and microwave instruments

Standards-based programmable instruments are prioritized.

Beamex

documenting calibrators · process calibration systems

Digital calibration workflows and field-device protocols require profile-specific review.

Druck / Baker Hughes

pressure controllers · pressure calibrators · sensors

Pressure-calibration target ecosystem.

WIKA

pressure · temperature · process calibration

Protocol/model support is validated per profile.

Additel

pressure controllers · pressure calibrators · temperature calibrators

Protocol/model support is validated per profile.

Tektronix / Keithley

oscilloscopes · source measure units · DMMs · electrical test

Electrical/electronic calibration target ecosystem.

Vaisala

humidity · temperature · environmental measurement

Read and adjustment capabilities remain separate.

Mettler Toledo

balances · mass and laboratory weighing

Serial/network command sets require model validation.

Sartorius

balances · mass and laboratory weighing

Serial/network command sets require model validation.